The TS2 Test Box
module simulates a TS2 cabinet (terminal facility) and allows the user to change any BIU
input and read
all BIU outputs using the SDLC communications port. The TS2 Test Box can also be used with
SimTraffic CI to simulate Synchro data files before deploying a timing plan to the field.
The size of
the TS2 Test Box is only 7" x 5"x 2", but the unit contains 8 terminal
facility BIU's and 8 detector BIU's that communicate with the controller over an SDLC
cable. The Test Box communicates with a computer over and RS-232 interface (serial
port). The Test Box software runs under Windows 95/98/NT and allows you to toggle all
controller inputs with a click of your mouse and view 16 load switch channels in
real-time.
Features
Compatibility
Eagle Traffic Control EPAC 300, Genesis M40
Econolite ASC/2-1000, ASC/2-2100
Naztec 980, 981
Peek Traffic Systems TS2 3000
* All
controllers with TS2 Compliant SDLC Interface
Included Components
MS Windows 95/98/NT Software
TS2 Test Box
AC Power Adapter
EIA 485 SDLC Controller to Test Box Communications Cable
EIA 232 PC to Test Box Communications Cable
Functional
Fully emulates all SDLC MMU Frames
Fully emulates all SDLC Terminal & Facilities CIU Frames
Fully emulates all SDLC Detector BIU Frames
Physical
7" x 5" x 2" (17.78 cm x 12.7 cm x 5.08 cm)
Electrical
Requires 8VDC @ 600 ma (110 VAC adapter included)
Assembly is fully repairable IC Socketed PC board design
EIA 232 9-pin female Test Box to PC Port
EIA 485 5-pin male Test Box to Controller Port
Ordering information
Please contact
Sales at Fortran
Traffic Systems Limited for ordering information.