Differential Mode:
400 A (8x20 ms)
Common Mode: 1000 A (8x20 ms)
Estimated
Occurrences
500 @ 200 A
Response
Time
< 5ns
Input
Capacitance
35pF @ 1KHz with 50
VDC Bias
Temperature
-40º C to +85º C
Weight
3 oz.
Dimensions
1.0625" x
1.0625" x 1.375"
Mounting
No 10-32 x 3/8"
bolt
Clamp
Voltage
@ 400 A, Diff Mode:
30 V max
Installation
One SRA-6LC provides protection for one (1) loop amplifier.
The SRA-6LC should be installed as close as possible to the point where the detector loop
wires enter the controller cabinet. Connect one of the flexible leads to each end of the
loop wires. The common connection on each SRA-6LC, (10-32 x 3/8" bolt) should be
connected to earth ground.
NOTES:
Optimum performance is obtained by shortening the flexible
leads as much as possible.
Provide the lowest possible impedance to ground in the
cabinet.