Controllers Area Home |
Other Product Specs
|
Model 722TXC
High Speed Dual Channel Detector
|
| The Naztec
Model 722 high-speed dual channel Inductive Loop Detector uses state of the art
technology to provide a robust and reliable rack mounted vehicle detection device.
Automatic self-tuning and fifteen selectable sensitivity levels ensure trouble-free
operation. Crosstalk between adjacent loops is minimized by selecting one of four
different oscillator frequencies for each loop. Crosstalk between adjacent channels is
eliminated by sequential scanning. As each loop is scanned, the other 3 channels are
turned off.
The Model 722 is capable of up to four operating modes. In Pulse
Mode, the detector provides a 150 millisecond pulse in response to a
detection, useful for counting and volume calculations. In Presence Mode,
the output from the detector is active as long as a vehicle is present on the loop. In Short
Presence Mode*, presence detection is limited to 20 minutes in length.
In Presence Timing Mode*, presence detection length is
programmable in 2 second intervals from 2 to 2022 seconds. The Model 722 detector also
provides a count output pin for each channel that outputs a 150 ms pulse each time a car
enters the loop. |

|
The Delay Timing option causes the output to be delayed up to 63
seconds after the beginning of the detection. The Extend Timing
option allows the output to remain active up to 15.75 seconds after the end of the
detection. In pulse mode, the minimum gap between vehicles can be set from .5 seconds to
2.25 seconds. The use of separate LEDs for detection and fault information eases setup and
diagnostics. The DETECT LED provides separate indications for detect, delay, and
extension. The FAULT LED uses 8 Hz, 2 Hz, 1/2 Hz, and continuous-on modes to indicate loop
shorted, opened, inductance change of more than 25%, and watchdog reset, respectively. An
RS232 communications port is provided, enabling the detector to be scanned for various
detection state, status, and programmed parameters. |
|
Features
 |
Rack-mounted, self-tuning high
speed dual channel model |
 |
Fifteen switch-selectable
sensitivity levels |
 |
Four switch-selectable frequencies
and sequential scanning operation minimizes crosstalk |
 |
Four selectable operating modes:
Pulse, Presence, Short Presence*, and Presence Timing (Texas Presence)* |
 |
Separate count output pins |
 |
Delay and extension timing* |
 |
Separate count outputs for each
presence indicator |
 |
Detection LED provides separate
indications for presence, delay and extension |
 |
Diagnostic LEDs indicate four
types of faults |
 |
Reset button to clear faults and
re-tune |
 |
Optional RS232 communications port |
 |
Versions available to meet or
exceed NEMA TS1, TS2 and Caltrans detector specifications |
* Denotes optional features |
Ordering information
Please contact Sales
at Fortran Traffic Systems Limited for ordering information. |
|
|