HomeControllers Area Home | Other Product Specs 

Naztec MMU 516 Malfunction Management Unit

 


The Naztec Model MMU 516 Malfunction Management Unit is an enhanced MMU that monitors up to 16 traffic signal indications (channels) for conflict, improper sequencing, incorrect timing, and improper signal voltage levels. The MMU 516 is fully compliant with NEMA Standard TS2-1992. The MMU 516 is also capable of operating in older TS1 type cabinets, and is compatible with 12-channel Conflict Monitor Units conforming to the NEMA Standard TS1-1989.

All connectors, indicators and operator controls are
located on the front panel of the MMU 516. Channel and control input signals and relay output connections are made through two MIL-C-26482 connectors, and the SDLC Port is an A-size, 15 contact, D shell connector. The TS232 Port is excellent for tracking important phase output data back to the controller or to a PC for logging. The programming card and the AC line fuse are easily accessed from the front panel.



wpe1.jpg (10781 bytes)

The MMU 516 provides a Reset Timeout feature to prevent a broken switch or accidental wiring fault from holding the unit in the reset state for an extended period of time. LED indicators, in addition to the TS2 specified indicators, include Dual Indication Fault, Yellow+Red Clearance Fault, Programming Card Ajar, Field Check (active channels do not match SDLC message from controller) Fault, and LEDs for two +24VDC input faults and CVM input faults. Status indicators provided include: AC Line Power, Type 12 Indicator, SDLC Transmitter Active, and SDLC Msg Received.

For added safety, the MMU 516 performs continuous diagnostic tests during all operating modes. All memory elements, the microprocessor, operating voltages, and critical circuitry are checked.


Features

Meets and exceeds all TS2 specifications
High Speed internal data transfer and communications via an SDLC port
High speed external data transfer via RS-232 port
Tri-Colour LEDs Red, Yellow, Green for channel display
LED indicator lamps for operation analysis
Removable program card
High performance machine tooled sockets for integrated circuit mounting

Programming

Minimum flash, 0-16 seconds
Short yellow per channel
Programmable sequence monitor
Latch selectable options

Indications

Conflict LED
Red Fail LED
24 V-1
24 V-2
Controller Voltage Monitor
Red+Yel Clearance
Clearance

Diagnostics
Port 1 Fault, Tx, Rx
Program Card Ajar
Indication Fail LED
Field Check
Power LED
Type 12 Mode

Environmental

Operating Temperature: -34º C to +74º C
Storage Temperature: -45º C to +85º C
Humidity: Less than 95% non-condensing to +43º C

NEMA+ Features

Meets and exceeds TS2-1992 Specifications
Operates in TS1 Cabinets
EPROM Memory/No batteries
Machine tooled socket I.C.'s
Programmable Minimum Flash Time
Latch 24 V Failures
Latch CVM Failure
Enhanced Monitoring

Electrical

Power Line Voltage: 75 to 150 VAC, RMS
Line Frequency: 57 to 63 Hz, 60Hz nominal
Power Consumption: 10 watts, typical
Fuse, Front Panel, 0.5A Slow Burn

Monitoring Voltage

Pickup: 96+/- 2.5 Volts AC, RMS
Dropout: 91+/- 2.5 Volts AC, RMS
Hysteresis: 4+/- 1.0 Volts AC, RMS

Dimensions

Height:  10.5 inches
Width:  4.5 inches
Depth:  10.9 inches

Ordering information

Please contact Sales at Fortran Traffic Systems Limited for ordering information.

 
 

Last updated: November 12, 2007

Fortran Traffic Systems Limited, a member of the Guild Group of companies
470 Midwest Road, Toronto, Ontario, Canada M1P 4Y5   Telephone: (416) 288-1320   Toll Free: (800) 387-4555

Legal Statement