wpe1.jpg (2048 bytes)Controllers Area Home | Other Product Specs 

Naztec Series 500 NEMA Conflict Monitor

 


The Naztec Series 500 NEMA Conflict Monitor is an enhanced keyboard-programmable conflict and power monitor that exceeds NEMA TS1 specifications. User interface is simplified by an LCD display and menu-driven software. In addition to standard NEMA requirements, the Series 500 Monitor can be programmed to monitor for short yellow and green intervals, sequence failures, and red failures. Failures can be either logged or latched. A real-time clock allows time and date stamping of all events. LED indicators are used to display all failures. The RS-232 port may be used to interface with a personal computer, printer, or traffic control system. Port setup including baud rate selection is accomplished via the keyboard. Printed reports include Program Options, Fault History, Power History, Tracing, and Program Card. The Series 500 monitor utilizes a standard NEMA program card.


cm500.gif (18717 bytes)


Features

Backlit supertwist 4x16 temperature compensated LCD display
MENU DRIVEN colour coded 20-key tactile and audio feedback keyboard
Real-time display of AC/DC cabinet voltage conditions
supports 9600 baud RS232 communications
Large dedicated RESET button
Meets and exceeds NEMA TS1-1989 functional and environmental specifications
Security codes are provided for up to 64 individual users

Programming

Short yellow per channel
Short green per channel
Programmable sequence monitor
Red fail inhibit, per channel
Log and latch selectable options
Date & time

Indications

Power LED
Conflict LED
Red Fail LED
Indication Fail LED
MIN/SEQ Fail LED

+24V LED
CVM LED
Program Card LCD
4x16 Supertwist LCD

Security

Unique access codes for 64 users

Environmental

Temperature: -30º F to 165º F
Humidity: 0 to 95%

NEMA+ Features

Meets and exceeds TS1-1989 Specifications
Utilizes standard TS1 program card
EPROM Memory/No batteries
Time clock backed by super capacitor
Monitor/lob all AC disturbances
Audio and tactile keyboard feedback
Machine tooled socket I.C.'s

Reports

Program Options
Fault History
Power History
Trace, previous states recorded
Reads program

Communications

Keyboard programmable baud rates
RS232 Interface
Printer, Notebook, System Comm.

Electrical

Power Line Voltage: 75 to 160 VAC, RMS
Line Frequency: 57 to 63 Hz, 60Hz nominal
Power Consumption: 9 watts, typical
Fuse, Front Panel, 1 Amp

Monitoring Voltage

Pickup: 100+/- 2.5 Volts AC, RMS
Dropout: 92.5+/- 2.5 Volts AC, RMS
Hysteresis: 7.5+/- 1.0 Volts AC, RMS

Dimensions

Height:  10.5 inches
Width:  4.5 inches
Depth:  10.9 inches
 

Ordering information

Please contact Sales at Fortran Traffic Systems Limited for ordering information.

 
 

Last updated: November 12, 2007