Controllers Area Home |
Other Product Specs
|
710 TX/I
Single Channel Loop Detector
|
The Naztec Model 710-TX/I Inductive Loop Detector uses state of
the art technology to provide a robust and reliable stand-alone
vehicle detection device. Automatic self-tuning and twelve selectable sensitivity levels
ensure trouble-free operation. Crosstalk is minimized by selecting one of four different
oscillator frequencies for each adjacent loop.The
710-TX/I is capable of four operating modes. In Pulse Mode, the
detector provides a 150-200 millisecond pulse in response to a detection, useful for
counting and volume calculations. In Presence Mode, the output
from the detector is active as long as a vehicle is present on the loop. In Short
Presence Mode, presence detection is limited to 20 minutes in length. In Presence
Timing Mode, presence detection length is programmable in 2 second intervals
from 2 to 2022 seconds. The Delay Timing feature causes the
output to be delayed up to 63 seconds (programmable in 1 second intervals) after the
beginning of the detection. The Extend Timing feature
allows the output to remain active up to 15.75 seconds (programmable in .25 second
intervals) after the end of the detection. In pulse mode, the minimum gap between vehicles
can be set from .5 seconds to 2.25 seconds. |

|
| The use of
separate LEDs for detection and fault information eases setup and diagnostics. The DETECT
LED indicates when a vehicle is on the loop or if Delay or Extension is active A 2 Hz
flash rate indicates Delay, while an 8 Hz flash indicates Extend. The FAULT LED uses 8 Hz,
2 Hz, 1/2 Hz, and continuous-on modes to indicate loop shorted, opened, inductance change
of more than 25%, and watchdog reset, respectively. |
Features
 |
Stand-alone, single channel model |
 |
Self-tuning |
 |
Twelve switch-selectable
sensitivity levels |
 |
Four switch-selectable frequencies
minimize crosstalk |
 |
Four selectable operating modes:
Pulse, Presence, Short Presence and Presence Timing (Texas Presence) |
 |
Adjustable gap timing in pulse
mode |
 |
Delay and extension timing |
 |
Vehicle count outputs from
presence detectors available as separate pins |
 |
Detection LED provides separate
indications for presence, delay, and extension |
 |
Diagnostic LEDs indicate four
types of faults |
 |
Reset button to clear faults and
re-tune |
 |
Meets or exceeds NEMA TS1
specifications for inductive loop detectors |
|
Ordering information
Please contact Sales