Specifications
Sensor Outputs
Real-time presence data in 10 lanes
Maximum number of zones: 8
Maximum number of channels: 4 (4 Output, Contact Closures)
User-selectable channel assignments
OR logic used to combine multiple zones to a channel output
Channel output extend and delay functionality
Algorithms mitigate detections from wrong way or cross traffic
Fail-safe mode for contact closure outputs if communication is lost
Detectable Area
Detection range: 6 to 100 ft. (1.8 to 30.5 m)
Field of view: 90 degrees
Flexible lane configuration support including:
Up to 10 lanes
Curved lanes
Islands and medians
System Hardware
A SmartSensor Matrix corner radar for each approach
A traffic cabinet preassembled backplate with:
AC/DC power conversion
Surge suppression
Terminal blocks for cable landing
Communication connection points
Cabinet side mount or rack mount
Contact closure input file cards:
2 or 4 channel
Compatible with industry standard detector racks
Maintenance
No cleaning or adjustment necessary
No battery replacement necessary
Recalibration is not necessary
Physical Properties
Weight: 4.2 lbs. (1.9 kg)
Physical dimensions: 13.2 in. × 10.6 in. × 3.3 in. (33.5 cm x 26.9 cm x 8.4 cm)
Resistant to corrosion, fungus, moisture deterioration, and ultraviolet rays
Enclosure: Lexan EXL polycarbonate
Outdoor weatherable: UL 746C
Watertight by NEMA 250 standard
NEMA 250 compliant for:
External icing
Hose down
4X corrosion protection
Gasket
Withstands 5 ft. (1.5 m) drop
Connector: MIL-C-26482
Rotational backplate for 360º of roll
Power
Power consumption: 9 W
Supply voltage: 9–28 VDC
Communication Ports
Two half-duplex RS-485 com ports support:
Dedicated detection comms
Configuration, verification or traffic display without disrupting detection comms
Firmware upgradability over any com port
User configurable:
Response delay
Push port
Radar Design
Operating frequency: 24.0 to 24.25 GHz (K-band)
Matrix of radars
No manual tuning to circuitry
Transmits modulated signals generated digitally
No temperature-based compensation necessary
Bandwidth stable within 1%
Printed circuit board antennas
Antenna vertical 6 dB beam width (two-way pattern): 65°
Horizontal field of view: 90 degrees
Antenna two-way sidelobes: -40dB
Transmit bandwidth: 245 MHz
Un-windowed resolution: 2 ft. (0.6 m)
RF channels: 8
Self-test for verifying hardware functionality
Diagnostics mode for verifying system functionality
Configuration
Automatic and manual configuration of lanes, stop bars and zones
Lane positioning increment: 1 ft. (0.3 m)
Four-sided zones of any shape and size
Overlapping zones supported
Sensor reconfiguration without detection disruption supported
Graphical user interface with traffic pattern display
Windows Mobile–compatible software
Supported operating systems:
Windows Mobile v 5.0 or greater (Socket Mobile 650-M)
Windows XP
Windows Vista
Software-supported functionality:
TCP/IP connectivity
Sensor configuration back-up and restore
Backed-up sensor configurations can be viewed and edited
Real-time traffic visualization for performance verification and traffic display
Zone and channel actuation display
Virtual sensor connections for demonstration and training
Local or remote sensor firmware upgradability
Operating Conditions
Accurate performance in:
Rain up to 1 in. (2.5 cm) per hour
Freezing rain
Snow
Wind
Dust
Fog
Changing temperature
Changing lighting (even direct light on sensor at dawn and dusk)
Ambient operating temperature: -40°F to 165°F (-40°C to 74°C)
Humidity: Up to 95% RH (noncondensing)
Testing
Tested under FCC CFR 47, part 15, section 15.249
FCC certification on product label
FCC regulation-compliant for life of the sensor
Tested under IEC 6100-4-5 class 4
Tested under NEMA TS2-2003
Shock pulses of 10g, 10ms half sine wave
Vibration of 0.5g up to 30 Hz
300 V positive/negative pulses
Stored at -49ºF (-45ºC) for 24 hours
Stored at 185ºF (85ºC) for 24 hours
Operation at -29.2ºF (-34ºC) and 10.8 VDC
Operation at -29.2ºF (-34ºC) and 26.5 VDC
Operation at 165.2ºF (74ºC) and 26.5 VDC
Operation at 165.2ºF (74ºC) and 10.8 VDC
Manufacturing
Manufactured in the USA
Surface mount assembly
IPC-A-610C Class 2–compliant
Operational testing:
Sub-assembly test
48-hour unit level burn-in
Final unit test
Unit test results available
Warranty
Two-year warranty against material and workmanship defect